超濾設(shè)備常見(jiàn)故障發(fā)生的原因及排除方法
Causes and troubleshooting of common faults in ultrafiltration equipment
1、進(jìn)水壓力低或進(jìn)水量不足
1. Low influent pressure or insufficient intake of water
可能原因:超濾預(yù)處理堵塞、超濾進(jìn)水泵壓力不夠、管徑偏小、閥門(mén)故障
Possible reasons: Ultrafiltration pretreatment blockage, insufficient pressure of ultrafiltration intake pump, smaller pipe diameter, and valve failure.
排除手段:清洗或更換過(guò)濾材料或裝置、更換更大的增壓泵、換管徑更大的管、更換閥門(mén)
Elimination means: cleaning or replacing filter materials or devices, replacing larger booster pumps, replacing pipes with larger diameters, and replacing valves.
2、產(chǎn)水量下降超過(guò)初始穩(wěn)定產(chǎn)水量的20%
2. Water production decreased by more than 20% of the initial stable yield.
可能原因:超濾膜被污染、跨膜壓差太小、原液水質(zhì)惡化、原液溫度降低、預(yù)處理供水不足、維護(hù)不當(dāng)
Possible reasons: ultrafiltration membrane is polluted, transmembrane pressure difference is too small, the quality of raw water is deteriorated, the temperature of raw fluid is reduced, pretreatment is insufficient, and maintenance is improper.
排除手段:進(jìn)行化學(xué)清洗和加藥殺菌、增大進(jìn)水壓力,但不得超過(guò)0.3Mpa.且TMP小于0.2Mpa、改善前處理,使之達(dá)到超濾進(jìn)水要求、升高原液溫度或加大進(jìn)水壓力但不得超過(guò)0.3Mpa.且TMP小于0.2Mpa、檢查及改進(jìn)預(yù)處理、加強(qiáng)維護(hù),并更換損壞設(shè)備
Elimination means: chemical cleaning and adding medicine and sterilization, increase water pressure, but not more than 0.3Mpa. and TMP less than 0.2Mpa, improve the pretreatment, make it meet the requirements of ultrafiltration, increase the temperature of the raw liquid or increase the pressure of water but not more than 0.3Mpa. and TMP less than 0.2Mpa, check and improve the pretreatment, strengthen maintenance, and replace. Damage equipment
3、壓力表壓力突然升高
3. A sudden increase in pressure gauge pressure
可能原因:氣動(dòng)蝶閥失靈
Possible reasons: the failure of pneumatic butterfly valve
排除手段:檢查氣動(dòng)蝶閥或控制電路的故障
Elimination means: check the malfunction of pneumatic butterfly valve or control circuit.